254749 - NF63-SV 3P 40A
Circuit breaker 3pole. In = 40A; Icu = Ics = 7,5kA at AC 440V
Materiale standard
Classe logistica: A -
254909 - NF125-SGV 3P 20-25A
Circuit breaker 3pole. Ir = 20 - 25A; Icu = Ics = 36kA at AC 440V
Materiale standard
Classe logistica: A -
255123 - NF250-SGV 4P 175-250A
Circuit breaker 4pole. Ir = 175 - 250A; Icu = Ics = 36kA at AC 440V
Materiale standard
Classe logistica: A -
254799 - NF63-HV 4P 63A
Circuit breaker 4pole. In = 63A; Icu / Ics = 10 / 8kA at AC 440V
Materiale standard
Classe logistica: C -
254912 - NF125-SGV 3P 35-50A
Circuit breaker 3pole. Ir = 35 - 50A; Icu = Ics = 36kA at AC 440V
Materiale standard
Classe logistica: A -
254684 - NF32-SV 3P 10A
Circuit breaker 3pole. In = 10A; Icu = Ics = 2,5kA at AC 440V
Materiale standard
Classe logistica: A -
254975 - NF125-HGV 4P 45-63A
Circuit breaker 4pole. Ir = 45 - 63A; Icu = Ics = 65kA at AC 440V
Materiale standard
Classe logistica: C -
255035 - NF125-HEV 4P 63-125A
Circuit breaker 4pole. Ir = 63 - 125A; Icu = Ics = 65kA at AC 440V
Materiale standard
Classe logistica: C -
254965 - NF125-HGV 3P 35-50A
Circuit breaker 3pole. Ir = 35 - 50A; Icu = Ics = 65kA at AC 440V
Materiale standard
Classe logistica: C -
255113 - DSN250-SGV 3P
Switch-disconnector 3pole. In max = 250A
Materiale standard
Classe logistica: A -
254796 - NF63-HV 4P 40A
Circuit breaker 4pole. In = 40A; Icu / Ics = 10 / 8kA at AC 440V
Materiale standard
Classe logistica: A -
254948 - NF125-LGV 4P 45-63A
Circuit breaker 4pole. Ir = 45 - 63A; Icu = Ics = 50kA at AC 440V
Materiale standard
Classe logistica: C -
255080 - NF250-SV 3P 200A
Circuit breaker 3pole. In = 200A; Icu = Ics = 36kA at AC 440V
Materiale standard
Classe logistica: A -
254989 - NF125-RGV 3P 20-25A
Circuit breaker 3pole. Ir = 20 - 25A; Icu = Ics = 125kA at AC 440V
Materiale standard
Classe logistica: C -
254746 - NF63-SV 3P 20A
Circuit breaker 3pole. In = 20A; Icu = Ics = 7,5kA at AC 440V
Materiale standard
Classe logistica: C -
254941 - NF125-LGV 3P 56-80A
Circuit breaker 3pole. Ir = 56 - 80A; Icu = Ics = 50kA at AC 440V
Materiale standard
Classe logistica: C -
254683 - NF32-SV 3P 6A
Circuit breaker 3pole. In = 6A; Icu = Ics = 2,5kA at AC 440V
Materiale standard
Classe logistica: B -
255118 - NF250-SGV 3P 125-160A
Circuit breaker 3pole. Ir = 125 - 160A; Icu = Ics = 36kA at AC 440V
Materiale standard
Classe logistica: A -
255137 - NF250-HGV 3P 140-200A
Circuit breaker 3pole. Ir = 140 - 200A; Icu = Ics = 65kA at AC 440V
Materiale standard
Classe logistica: C -
254791 - NF63-HV 4P 16A
Circuit breaker 4pole. In = 16A; Icu / Ics = 10 / 8kA at AC 440V
Materiale standard