Products for the Better
-
254949 - NF125-LGV 4P 56-80A
Circuit breaker 4pole. Ir = 56 - 80A; Icu = Ics = 50kA at AC 440V
Standard Artikel
Logistikklasse: C -
254978 - NF125-HGV 4P 90-125A
Circuit breaker 4pole. Ir = 90 - 125A; Icu = Ics = 65kA at AC 440V
Standard Artikel
Logistikklasse: C -
255078 - NF250-SV 3P 160A
Circuit breaker 3pole. In = 160A; Icu = Ics = 36kA at AC 440V
Standard Artikel
Logistikklasse: A -
254759 - NF63-SV 4P 20A
Circuit breaker 4pole. In = 20A; Icu = Ics = 7,5kA at AC 440V
Standard Artikel
Logistikklasse: C -
254749 - NF63-SV 3P 40A
Circuit breaker 3pole. In = 40A; Icu = Ics = 7,5kA at AC 440V
Standard Artikel
Logistikklasse: A -
254948 - NF125-LGV 4P 45-63A
Circuit breaker 4pole. Ir = 45 - 63A; Icu = Ics = 50kA at AC 440V
Standard Artikel
Logistikklasse: C -
254780 - NF63-HV 3P 16A
Circuit breaker 3pole. In = 16A; Icu / Ics = 10 / 8kA at AC 440V
Standard Artikel
Logistikklasse: B -
254924 - NF125-SGV 4P 70-100A
Circuit breaker 4pole. Ir = 70 - 100A; Icu = Ics = 36kA at AC 440V
Standard Artikel
Logistikklasse: A -
254686 - NF32-SV 3P 16A
Circuit breaker 3pole. In = 16A; Icu = Ics = 2,5kA at AC 440V
Standard Artikel
Logistikklasse: A -
255168 - NF250-SEV 4P 80-160A
Circuit breaker 4pole. Ir = 80 - 160A; Icu = Ics = 36kA at AC 440V
Standard Artikel
Logistikklasse: C -
204540 - NF125-SGW 3P RT 16-25A W
Circuit breaker 3pole. Ir = 16 - 25A; Icu = Ics = 36kA at AC 440V
Abgekündigter Artikel
-
255171 - NF250-HEV 3P 125-250A
Circuit breaker 3pole. Ir = 125 - 250A; Icu = Ics = 65kA at AC 440V
Standard Artikel
Logistikklasse: B -
255079 - NF250-SV 3P 175A
Circuit breaker 3pole. In = 175A; Icu = Ics = 36kA at AC 440V
Standard Artikel
Logistikklasse: A -
255077 - NF250-SV 3P 150A
Circuit breaker 3pole. In = 150A; Icu = Ics = 36kA at AC 440V
Standard Artikel
Logistikklasse: A -
254761 - NF63-SV 4P 30A
Circuit breaker 4pole. In = 30A; Icu = Ics = 7,5kA at AC 440V
Standard Artikel
Logistikklasse: C -
255138 - NF250-HGV 3P 175-250A
Circuit breaker 3pole. Ir = 175 - 250A; Icu = Ics = 65kA at AC 440V
Standard Artikel
Logistikklasse: C -
269402 - NF63-SV 3P 30A
Circuit breaker 3pole. In = 30A; Icu = Ics = 7,5kA at AC 440V
Standard Artikel
Logistikklasse: C -
254940 - NF125-LGV 3P 45-63A
Circuit breaker 3pole. Ir = 45 - 63A; Icu = Ics = 50kA at AC 440V
Standard Artikel
Logistikklasse: C -
577242 - NF100-SX 1P 15A CE
Circuit breaker 1pole. Ir = 15A; Icu = Ics = 200kA at AC 440V
Standard Artikel
Logistikklasse: A -
254781 - NF63-HV 3P 20A
Circuit breaker 3pole. In = 20A; Icu / Ics = 10 / 8kA at AC 440V
Standard Artikel
Logistikklasse: B
Ihrem Warenkorb hinzugefügt